APC GALAXY G3HT60KHB2S 300 60kVA 400V
Product Specifications
| MAIN INPUT VOLTAGE | 400 V 3 phases |
|---|---|
| OTHER INPUT VOLTAGE | 380 V 415 V |
| MAIN OUTPUT VOLTAGE | 400 V 3 phases |
| OTHER OUTPUT VOLTAGE | 380 V 415 V |
| RATED POWER IN W | 54000 W |
| RATED POWER IN VA | 60000 VA |
| OUTPUT CONNECTOR TYPE | Hard wire 5-wire (3P + N + E) 1 |
| BATTERY TYPE | Lead-acid battery |
| PROVIDED EQUIPMENT | CD with software Dust filter Installation guide Network management card Start-up service User manual |
| BYPASS WIRING CONFIGURATION | 5 wire (3P + N + E) |
|---|---|
| NUMBER OF POWER MODULE FREE SLOTS | 0 |
| NUMBER OF POWER MODULE FILLED SLOTS | 0 |
| REDUNDANT | No |
| HEIGHT | 190 cm |
|---|---|
| WIDTH | 70 cm |
| DEPTH | 95 cm |
| NET WEIGHT | 735 kg |
| MOUNTING PREFERENCE | No preference |
| USB COMPATIBLE | No |
| NETWORK FREQUENCY | 45…65 Hz |
|---|---|
| NUMBER OF INPUT CONNECTORS | 1 hard wire 5-wire (3P + N + E) |
| INPUT VOLTAGE LIMITS | 323…437 V adjustable 380 V 340…460 V adjustable 400 V 357…477 V adjustable 415 V 340…477 V |
| MAXIMUM INPUT CURRENT | 228 A |
| SWITCHING CURRENT CAPACITY | 160 A |
| MAX SHORT-TIME WITHSTAND CURRENT | 16 kA |
| INPUT HARMONIC DISTORTION | Less than 5 % for a full load |
| INPUT PROTECTION TYPE | 3-pole circuit breaker |
| INRUSH CURRENT | 200 A peak |
| LOAD POWER FACTOR | 0.5 leading to 0.5 lagging |
| INPUT POWER FACTOR AT FULL LOAD | 0.99 |
| MAXIMUM CONFIGURABLE POWER IN W | 54000 W |
|---|---|
| HARMONIC DISTORTION | Less than 5 % |
| OUTPUT FREQUENCY | 50/60 Hz +/- 5 % sync to mains 50/60 Hz +/- 1 Hz unsynchronized |
| CREST FACTOR | 3 : 1 |
| OUTPUT VOLTAGE TOLERANCE | +/- 2% static and 100% load step |
| OUTPUT HARMONIC DISTORTION | < 3% linear load and < 5% non-linear load |
| OUTPUT OVERLOAD OPERATION | 10 minutes at 125% and 30 seconds at 150% |
| REQUIRED OUTPUT CURRENT PROTECTION | 160 A |
| NEUTRAL OUTPUT CURRENT | 87 A |
| BYPASS TYPE | Built-in static bypass |
| MAXIMUM CONFIGURABLE POWER IN VA | 60000 VA |
| PRODUCT CERTIFICATIONS | CE EAC |
|---|---|
| STANDARDS | EN/IEC 62040-1 EN/IEC 62040-2 EN/IEC 62040-3 ISTA 2B IEC 62040-4 |
| AMBIENT AIR TEMPERATURE FOR OPERATION | 0…40 °C |
|---|---|
| RELATIVE HUMIDITY | 0…95 % |
| OPERATING ALTITUDE | 0…3000 ft |
| AMBIENT AIR TEMPERATURE FOR STORAGE | -15…40 °C |
| STORAGE RELATIVE HUMIDITY | 0…95 % |
| STORAGE ALTITUDE | 0.00…4572.00 m |
| ACOUSTIC LEVEL | 65 dBA |
| IP DEGREE OF PROTECTION | IP20 |
| EFFICIENCY | View Efficiency Graph |
|---|---|
| NUMBER OF BATTERY-FILLED SLOTS | 0 |
| NUMBER OF BATTERY-FREE SLOTS | 0 |
| ADDITIONAL INFORMATION | KW/kVA = 0.9 PF with ambient temp up to 25°C. kW/kVA = 0.8 PF with ambient temp above 25°C |
| BATTERY VOLTAGE | +/- 192 V (split battery referenced to neutral) |
| DISCHARGE BATTERY VOLTAGE | +/- 154 V |
| BATTERY POWER IN VAH | 0 VAh runtime |
| BATTERY LIFE | 3…5 year(s) |
| EXTENDED RUNTIME | 0 |
| PREINSTALLED DEVICE | Network management card |
|---|---|
| CONTROL PANEL | Multifunction LCD status and control console |
| EMERGENCY POWER OFF | Yes |
| UNIT TYPE OF PACKAGE 1 | PCE |
|---|---|
| NUMBER OF UNITS IN PACKAGE 1 | 1 |
| PACKAGE 1 HEIGHT | 197.8 cm |
| PACKAGE 1 WIDTH | 112 cm |
| PACKAGE 1 LENGTH | 82.4 cm |
| PACKAGE 1 WEIGHT | 755 kg |





Reviews